DL76 Data Logger
Kategori:Seametrics Flow Meters
GENERAL INFORMATION
The
DL76 is a battery-powered data logger that can be used with any
Seametrics flowmeter. It stores pulses for up to 3 years, depending on
the user-selected frequency of reading. Indicator lights on the unit
flash to indicate when it is functioning and when the battery is
low. The DL76 can be factory-mounted on the meter or remotely mounted.
Housings are rugged cast aluminum, gasketed for environmental
protection. When a DL76 logger is placed into operation, it is easily
set up using a laptop computer. Data is also retrieved from the DL76 by
means of a laptop and can be analyzed on the laptop or easily loaded on a
desktop computer for analysis.
*FlowInspector version 2
software (ordered separately) is required for the downloading, storing,
viewing, graphing, charting and printing of data in several formats.
FlowInspector requires a PC with Windows 98, NT, 2000, XP, Vista or
Windows 7; CD-Rom drive; 800 x 600 screen resolution; serial port
or USB/serial adapter; and a Seametrics DC3 data cable.
FlowInspector can be used with an unlimited number of dataloggers.
FEATURES
• Easy to set-up, easy to use
• Weeks/months/years of data storage
• User-selected sampling interval
• Data retrieval with laptop computer
• Single data retrieval device serves multiple data loggers
APPLICATIONS
• Water usage monitoring, reporting, and management
• Custody transfer regulation
• Peak demand monitoring
SPECIFICATIONS
Power
|
Size C 3.6 Vdc lithium battery (included)
|
Battery Life
|
Estimated life is 3-5 years depending on usage
|
Temperature
|
0˚ to 130˚ F (-18˚ to 54˚C)
|
Rate Units Volume
|
mL, liter, gallon, Imperial gallon, cubic foot, cubic meter,
million gallon
|
Time
|
Seconds, minutes, hours, days
|
Total Units
|
Liter, gallon, Imperial gallon, cubic foot, cubic meter, million
gallon, acre-foot, acre-inch, megaliter, thousand-gallon
|
Data Storage Capacity
|
Capacity at Sampling Interval
|
|
11 days
at 15 seconds
|
|
22 days
at 30 seconds
|
|
44 days at 60 seconds
|
|
6 months at 240 seconds
|
|
1 year at 480 seconds
|
|
3 years at 1450 seconds
|
Maximum Input Frequency
|
500 Hz
|
Indicators
|
Low battery; Power
|
Memory Wraparound
|
Selectable options (Stop or Overwrite)
|
Clock Accuracy
|
10 minutes/month (.02%)
|
Tidak ada komentar: