Turbine Flowmeter

Turbine Flow MeterStainless Steel Flow Meter
PVC Flow Meter
Water MeterFEATURES
• One moving part
• Low friction jewel bearings
• Field repairable without removal from the line
• Choice of materials for chemical compatibility
• Variety of displays and control
APPLICATIONS
• Water treatment
• Wastewater treatment
• Cooling water monitoring
• Industrial fluid control
GENERAL INFORMATION
This unique system of 2″ to 8″ turbine flow meters uses just one moving part, a precision helical rotor. Rotation of the rotor is electronically detected and processed. The high-quality jewel bearings and polished zirconia ceramic shafts minimize friction while providing long wear life in non-lubricating fluids. The entire rotor assembly can be easily removed for field service without removing the meter from the pipe.
WTP bodies are fabricated from Schedule 80 PVC fittings, WTC bodies from carbon steel tubing, and WTS bodies (available as special order) from stainless steel tubing. The turbine insert on WTC and WTS meters is machined from a stainless steel casting. The WTP turbine insert is machined from a solid piece of PVC (polypro in 2” size). Turbine rotors on all models are Kynar (PVDF).
WT flow meters can be ordered with various output options. The basic model (100) comes with pulse output only. An electronic display (Seametrics FT420) is mounted on the 101 model to display flow rate and total (resettable or non-resettable), and provide a programmable pulse or 4-20 mA output. Other electronics options include a blind 4-20 mA transmitter (AO55) on the 102 model and a battery-powered (FT415) rate/totalizer plus pulse output for applications that lack power (104 model). All of these controls/displays can be mounted on the meter or remotely mounted on a wall or panel up to 2,000 feet away. WTSeries flow meters are compatible for use with most other remote-mount Seametrics displays and controls as well.
Turbine Flow Meter Model :
1. WTS Turbine Flow Meter (  Stainless Steel Turbine Flow Meter )
  • Stainless-steel body turbine flow meter
  • In-line, individually-calibrated turbine meter maximizes accuracy
  • Turbine rotor is the only moving part, optimizing low-flow performance
  • Solid-state pickup
  • Electronic register can be meter-mounted or remote
  • Available with blind pulse or 4-20 mA output
  • Lightweight, corrosion-resistant 304SS (or optional 316SS) body
  • Flanges standard 3″ and above (2″ has female NPT threads)
2. WTP Turbine Flow Meter ( PVC Turbine Flow Meter )
  • PVC-body turbine flow meter
  • In-line, individually-calibrated turbine flow meter maximizes accuracy
  • Turbine rotor is the only moving part, optimizing low-flow performance
  • Solid-state pickup
  • Electronic register can be meter-mounted or remote
  • Available with blind pulse or 4-20 mA output
  • Materials are chemical-resistant
  • Can be ordered with stub ends (standard) or flanges (optional)

3.  WTC Turbine Flow Meter ( Carbon Steel Turbine Flow Meter )
  • In-line, individually-calibrated turbine flow meter maximizes accuracy
  • Turbine rotor is the only moving part, optimizing low-flow performance
  • Solid-state pickup
  • Electronic register can be meter-mounted or remote
  • Available with blind pulse or 4-20 mA output
  • Heavy-duty, fabricated steel body with shopcoat
  • Flanges standard 3″ and above (2″ has female NPT threads)

Senin, 14 Juli 2014

iMAG-SERIES Flanged Magmeter

iMAG-SERIES Flanged Magmeter
 
Deskripsi:
GENERAL INFORMATION
The iMAG-Series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3” to 12”
pipe in municipal or industrial water, wastewater, pump stations and packaged plant applications. The iMAG has no moving parts and electrodes are designed to discourage fouling. This magmeter requires no maintenance in applications where debris would impede mechanical meters. There are no parts to wear out. Minimal straight pipe requirements allow iMAG-Series meters to be used in piping configurations where there is little space between the meter and an elbow.
iMAG-Series meters are rated IP68 for applications where the meter may be under water up to a depth of 10 feet (3 meters)
for prolonged periods of time. Rate and total indication are standard. Rate and total units and pulse output are settable via the front panel touch key pad by
the user. The iMAG can be externally powered with 9-36 Vdc at 30 mA. The standard 20-foot (6 meter) cable also provides outputs for use with a variety of Seametrics and other displays and controls for remote reading, data logging and telemetry applications. 4-20mA passive current loop and high frequency outputs are optional. The iMAG 3600 remote display meter can be supplied with an optional internal AC power supply.


FEATURES
• Easy setup
• Minimal straight pipe
• Mounted or remote rate & total
• Tamper-evident seal
• NSF-61 approved
• IP68 rated


THE RIGHT METER FOR
• Water & wastewater
• Municipal
• Treatment plants
• Pump stations
• Packaged plants
• Filtration systems


SPECIFICATIONS
Pipe Size
3”,4”, 6”, 8”, 10”,12”
Flanges
150 lb. ANSI pattern
Pressur
150 psi (10.3 bar) working pressur
Temperature
Operating
10˚ to 130˚ F (-12˚ to 54˚ C)

Storage
-40˚ to 158˚ F (-40˚ to 70˚ C)
Accuracy
+/- 1% of reading +/- 0.25% of full-scale flow from low flow cutoff to maximum flow rate of 10 m/se
Low Flow Cutof
0.5% of maximum flow rat
Materials
 Body (3” Only)
Ductile cast iron, powder-coated w/NSF61 listed epoxy powde

      Body (4”-12”
Welded steel, epoxy-coated

      Liner (3” Only
Noryl®

       Liner (4”-12”)
Santoprene/Polypropylen

      Electronics Housing
Ductile cast iron, powder-coate

      Electrodes
316 stainless stee

      O-ring (3” Only)
EPDM
Display
       Type
128x64 dot-matrix LCD

      Digits
5 Digit Rate



      Units
Rate Volume Units
Rate Time Units
Total Volume Units

Gallons
Liters
Cubic Feet
Cubic Meters
Million Gallons
Mega Liters
Imperial Gallons
Million Imperial Gallons
Second
Minute
Hour
Day
Gallons
Gallons x 1000
Million Gallons
Liters
Liters x 1000
Mega Liters

Cubic Meters
Cubic Meters x 1000
Cubic Feet
Cubic Feet x 1000
Imperial Gallons
Imperial Gallons x 1000
Million Imperial Gallons
Power
DC Power
9-36 Vdc @ 250 mA max, 30 mA average

AC Power1 
85-264Vac, 50/60Hz, 0.12A
Telemetry Output
3.3V asynchronous receive and transmit (UART) signals, ASCII command-response protocol
Pulse Frequency Output
Signal
Current sinking pulse, isolated, 36 Vdc at 10 mA max

Pulse Rates
User-settable volume units/pulse. Pulse width is one-half of pulse period, 200 pulses/sec max
  Options
4-20mA Current Loop
Isolated, passive, 6-36Vdc, +/- 0.1% of pulse/frequency output HART compliant2

Digital Output
Isolated, open collector, 36Vdc @ 10mA max., frequency output up to 10kHz

Relay Output
Solid state relay, normally open, non-polarized, 28Vac/40Vdc @ 0.5A max, 33Hz max

Serial Communications2
Isolated, asynchronous serial RS485 or RS232, Modbus RTU protocol
Cable 
Control Cable
Six-conductor water-blocked cable, polyurethane jacket, 20ft (6m) standard length for power, pulse
frequency or optional outputs. Optional lengths up to 100’ available

Remote Display Cable (iMAG 3600)
33ft (10m) standard length may be shortened (by user in the field). Additional cable can be ordered and attached with the use of a junction box (purchased from a standard supplier) up to 100ft (30m) total
Conductivity
>20 microSiemens/cm
Empty Pipe Detection
Hardware/software, conductivity-based
Regulatory
(EN 61326) pending, NSF-61
Environmental
IP68 to 10ft (3m) depth

DL76 Data Logger


DL76 Data Logger
Deskripsi:
GENERAL INFORMATION
The DL76 is a battery-powered data logger that can be used with any Seametrics flowmeter. It stores pulses for up to 3 years, depending on the user-selected frequency of reading. Indicator lights on the unit flash to indicate when it is functioning and when the battery is low. The DL76 can be factory-mounted on the meter or remotely mounted. Housings are rugged cast aluminum, gasketed for environmental protection. When a DL76 logger is placed into operation, it is easily set up using a laptop computer. Data is also retrieved from the DL76 by means of a laptop and can be analyzed on the laptop or easily loaded on a desktop computer for analysis.
*FlowInspector version 2 software (ordered separately) is required for the downloading, storing, viewing, graphing, charting and printing of data in several formats. FlowInspector requires a PC with Windows 98, NT, 2000, XP, Vista or Windows 7; CD-Rom drive; 800 x 600 screen resolution; serial port or USB/serial adapter; and a Seametrics DC3 data cable. FlowInspector can be used with an unlimited number of dataloggers.


FEATURES
• Easy to set-up, easy to use
• Weeks/months/years of data storage
• User-selected sampling interval
• Data retrieval with laptop computer
• Single data retrieval device serves multiple data loggers


APPLICATIONS
• Water usage monitoring, reporting, and management
• Custody transfer regulation
• Peak demand monitoring


SPECIFICATIONS
Power
Size C 3.6 Vdc lithium battery (included)
Battery Life
Estimated life is 3-5 years depending on usage
Temperature
0˚ to 130˚ F (-18˚ to 54˚C)
Rate Units                                Volume
mL, liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon
                                                  Time
Seconds, minutes, hours, days
Total Units
Liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon, acre-foot, acre-inch, megaliter, thousand-gallon
Data Storage Capacity
Capacity                     at         Sampling Interval

11 days                       at               15 seconds

22 days                       at               30 seconds

44 days                       at                60 seconds

6 months                     at               240 seconds

1 year                           at                480 seconds

3 years                         at               1450 seconds
Maximum Input Frequency
500 Hz
Indicators
Low battery; Power
Memory Wraparound
Selectable options (Stop or Overwrite)
Clock Accuracy
10 minutes/month (.02%)