PT.WIRATAMA MITRA ABADI

PT.WIRATAMA MITRA ABADI

PT.WIRATAMA MITRA ABADI

PT.WIRATAMA MITRA ABADI

PT.WIRATAMA MITRA ABADI

PT.WIRATAMA MITRA ABADI

Rabu, 20 Agustus 2014

Flowmeter CS Instruments


CS INSTRUMENTS VA400

Flow sensor for compressed air and gases usable from 1/2″ to 12″ (DN300)

The VA 400 for consumption measurement of compressed air and gases in a robust housing with actual consumption in m³/h and counter in m³.
Special featues
  • Integrated display for m³/h and m³
  • Depth scale for accurate installation
  • Usable from 1/2″ to 12″ (DN 300)
  • Easy installation under pressure
  • 4…20 mA analogue output
    for m³/h resp. m³/min
  • Pulse output for m³
  • Inner diameter adjustable via keypad
  • Consumption counter resettable
Gas types adjustable via software:
air, nitrogen, argon,
helium, CO2, oxygen

Flowmeter CS Instruments


 CS INSTRUMENS VA 420  SERIES 

VA 420

Consumption counter with integrated measuring section (1/4″ to 2″ with/without weld neck flange)

Application-technological features of the consumption counters VA 420:
  • Easy and affordable installation
  • Units freely selectable via keypad m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm
  • Compressed air counter up to 1,999,999,999 m³. Resettable to “zero” via keypad
  • Analogue output 4…20 mA, pulse output (galvanically seperated)
  • High measuring accuracy also in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Gas types adjustable via software (nitrogen, oxygen, CO2, nitrous oxide, argon)
Application range of VA 420:
  • Compressed air balancing, compressed air consumption measurement
  • Leakage air / leak rate determination
  • Mobile compressed air measurement in front of single machines / plants
  • Flow measurement of process gases like e. g. nitrogen, CO2, oxygen, argon, nitrous oxide
  • Flow measurement at nitrogen generators

Safty Valve Elektrogas


 

AUTOMATIC SAFTY VALVE

VMH VMP

Safety shut off valves, slow opening and fast closing with hydraulic or pneumatic actuator
The VMH type valve is a safety shut off valve for gaseous media operated by hydraulic actuator. It is suitable for gas blocking and releasing controls, as required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns and gas consuming appliances.
When the actuator is energized, the valve opens slowly (some seconds); as soon as power supply stops, the valve closes immediately (<1 continuous="" ed="" for="" is="" it="" p="" qualified="" sec="" service="">
The hydraulic actuator can be replaced with a pneumatic actuator (VMP series) if compressed air is available in the plant.
Material/Connections
AlSiDN65 … DN200
Operating pressure
0 … 200 mbar
0 … 500 mbar
0 … 1300 mbar
0 … 1600 mbar
Gas type
Air and non-aggressive gases (Family 1-2-3, EN 437)
Special version for Biogas/COG
Approvals
EC-type tested and certified according to EN 161

Flowmeter Gerrand

 GERAND FLOW METER
 FIRE PUMP TEST METER MODE L-K
Gerand Flow Meter Hydrant use to know and flow capacity testing of water flow system of fire.
Gerand is a flow meter to the type / model of Venturi Flow Meters are only used for the reading of the flow capacity or flow rate of the water flowing from the hydrant system and does not calculate or totalizer volume of water flowing from the hydrant system.

Gerand Venturi flow meter has two models namely Model K and Model M.

FIRE PUMP TEST METER MODE L-K

Gerand Hydrant flow meters have a system that has three forms, namely: Butt Weld, Grooved, Flange.

GERAND FLOW METER
 FIRE PUMP TEST METER MODE L-K

 - RATING 500 PSI -
 ( BUTT WELD, GROOVED ENDS & 300 # FLANGED)
 - RATING 275 PSI -
 ( FOR 150 # FLANGED UNITS ONLY)

 A calibrated venturi and attached GPM meter installed on the discharge of a fire pump to accurately determine pump performance.

 4-1/ 2" dial meter is shipped for mounting on venturi bracket. If meter is to be remote mounted, consult factory on special hose lengths.

 Click here for the most common and additional Model " K" FM approved pump GPM/ Line size combinations of fire pump test meters.

 Dual LPM/ GPM Scales Available.
 VENTURI SYSTEM
 MODEL NO.
 - K-25-1-1/ 4( 616)
 - K-50-2( 685)
 - K-100-2-1/ 2( 746)
 - K-150-3( 766)
 - K-200-3( 766)
 - K-250-4( 744)
 - K-300-4( 744)
 - K-450-4( 744)
 - K-500-5( 715)
 - K-750-6( 743)
 - K-1000-6( 743)
 - K-1250-6( 743)
 - K-1500-8( 750)
 - K-2000-8( 750)
 - K-2500-8( 750)
 - K-3000-8( 750)
 - K-3500-10( 755)
 - K-4000-10( 755)
 - K-4500-10( 755)
 - K-2000-12( 750)


TYPE  ( BUTT WELD, GROOVED ENDS & 300 # FLANGED)
 - RATING 500 PSI -
 TYPE  BUTT WELD

 TYPE   GROOVED ENDS


 ( FOR 150 # FLANGED UNITS ONLY)
- RATING 275 PSI -

Flowmeter Gerand For Hydrant And Chiller

 GERAND FLOW METER
 FIRE PUMP TEST METER MODE L-K
Gerand Flow Meter Hydrant use to know and flow capacity testing of water flow system of fire.
Gerand is a flow meter to the type / model of Venturi Flow Meters are only used for the reading of the flow capacity or flow rate of the water flowing from the hydrant system and does not calculate or totalizer volume of water flowing from the hydrant system.

Gerand Venturi flow meter has two models namely Model K and Model M.

FIRE PUMP TEST METER MODE L-K 

Gerand Hydrant flow meters have a system that has three forms, namely: Butt Weld, Grooved, Flange.

GERAND FLOW METER
 FIRE PUMP TEST METER MODE L-K

 - RATING 500 PSI -
 ( BUTT WELD, GROOVED ENDS & 300 # FLANGED)
 - RATING 275 PSI -
 ( FOR 150 # FLANGED UNITS ONLY)

 A calibrated venturi and attached GPM meter installed on the discharge of a fire pump to accurately determine pump performance.

 4-1/ 2" dial meter is shipped for mounting on venturi bracket. If meter is to be remote mounted, consult factory on special hose lengths.

 Click here for the most common and additional Model " K" FM approved pump GPM/ Line size combinations of fire pump test meters.

 Dual LPM/ GPM Scales Available.
 VENTURI SYSTEM
 MODEL NO.
 - K-25-1-1/ 4( 616)
 - K-50-2( 685)
 - K-100-2-1/ 2( 746)
 - K-150-3( 766)
 - K-200-3( 766)
 - K-250-4( 744)
 - K-300-4( 744)
 - K-450-4( 744)
 - K-500-5( 715)
 - K-750-6( 743)
 - K-1000-6( 743)
 - K-1250-6( 743)
 - K-1500-8( 750)
 - K-2000-8( 750)
 - K-2500-8( 750)
 - K-3000-8( 750)
 - K-3500-10( 755)
 - K-4000-10( 755)
 - K-4500-10( 755)
 - K-2000-12( 750)


TYPE  ( BUTT WELD, GROOVED ENDS & 300 # FLANGED)
 - RATING 500 PSI -
 TYPE  BUTT WELD

 TYPE   GROOVED ENDS

 ( FOR 150 # FLANGED UNITS ONLY)
- RATING 275 PSI -

Solenoid Valve For Gas

VMR Series

Safety solenoid valves for air and gas, fast opening and fast closing type
The VMR type valve is a fast opening solenoid valve that is normally closed.
When the coil is not energized the spring works on the disc keeping the gas passage closed. When the coil is powered the valve opens. When power is switched off the valve rapidly shuts.
This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, in industrial kilns and in all gas equipments which use gas solenoid valves (qualified for continuous service – 100% ED).


Material/Connections
CuZn Rp1/4 … Rp1/2
AlSi Rp3/8 … Rp2½
AlSi DN40 … DN150
Operating pressure
0 ... 200 mbar
0 ... 360 mbar
0 ... 500 mbar
Gas type
Air and non-aggressive gases (Family 1-2-3, EN 437)
Special version for Biogas/COG
Approvals
EC-type tested and certified according to EN 161

Solenoid Valve For Bio Gas



VMH VMP


Safety shut off valves, slow opening and fast closing with hydraulic or pneumatic actuator
The VMH type valve is a safety shut off valve for gaseous media operated by hydraulic actuator. It is suitable for gas blocking and releasing controls, as required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns and gas consuming appliances.
When the actuator is energized, the valve opens slowly (some seconds); as soon as power supply stops, the valve closes immediately (<1 continuous="" ed="" for="" is="" it="" p="" qualified="" sec="" service=""> The hydraulic actuator can be replaced with a pneumatic actuator (VMP series) if compressed air is available in the plant.


Material/Connections
AlSi DN65 … DN200
Operating pressure
0 … 200 mbar
0 … 500 mbar
0 … 1300 mbar
0 … 1600 mbar
Gas type
Air and non-aggressive gases (Family 1-2-3, EN 437)
Special version for Biogas/COG
Approvals
EC-type tested and certified according to EN 161